Charging performance test conditions:
(1) Discharge: the battery is discharged by 50%
(2) Stand still: the battery electrolyte temperature is cooled to 0℃ after discharge
(3) Charging: charge
at 14.4V for 10 minutes to record the maximum received charging current.
Electrode plate mixed carbon conductivity LOG
After mixing the carbon plate with the numerical value in the chart on the left Conductivity increased
by 42%
Low temperature discharge test conditions:
(1) Standstill: After fully charged, place it at -20℃ and freeze for 24 hours.
(2) Discharge: discharge cut-off voltage 7.2V, maximum discharge current in 5 seconds
According to IEC 60896-21:2004, IEC 60896-22:2004 high temperature float test conditions:
(1) Ambient temperature: 55±2℃ (2) Charging: charging voltage 13.5±0.05V (3) Floating charge time: 42±3 days
(4)
Discharging: After 42 days, cool down at room temperature for 12~24 hours. Discharge to 10.2V in 3 hours
(5) Termination condition: When the battery capacity in 3 hours is less than 80%, the test will be terminated
Lead-acid battery cycle life
Carbon lead battery cycle life
Floating life of lead-acid battery
Floating life of carbon lead battery